Control center devices =FIREscape
=PRODEX 500
PRODEX FIRESCAPE
FIRE ALARM CENTER, ADDRESSABLE PRODEX-PVE
• one loop card 1A integrated to motherboard MONITORING DEVICE FOR FIRE/FAULT/ADVANCE
• a second loop card 1A can be connected to the motherboard • notifies of a common: fire alarm, advance fire alarm or fault alarm
• 128 programmable groups • internal buzzer of an acknowledgeable device manually, other
• capable of maintaining 60Ah batteries
• two date and time lines for the mother card 2A alarms
• two monitored voltage outputs, EOL, 100mA are acknowledged from the fire alarm center
• dimensions 680x420x85 • the advance alarm has a di erent tone than the fire alarm
• operating voltage 16 - 30 VDC
FS-HOAN • dimensions 62 x 62 x 35 mm
ADDRESSABLE FIRESCAPE LOOP CARD
• addressable loop card for FIREscape center PRODEX-EIA
• max. 127 addresses SMOKEDETECT.DEACTIVATETIMER
• deactivation timer for smoke detector
PRODEX-HOCO 3.03 • deactivation time 30 min - 12 h (with 10 min accuracy)
CONVENTIONAL LINE CARD 8-LOOP • built-in buzzer
• eight lines • connected to the center using a CHQ-DIM(SCI) module
• maximum 32 detectors/line
• loop terminal TE-RH-E is delivered with the card (option)
• for the FIREscape center • operating voltage 8 - 40 VDC
• dimensions 125 x 150 x 28 mm
FS-LOOP-CARD-ADAPTER SIGMA-K11040M2 and SIGMA-K11080M2
EXPANSION CARD FIRE CENTER 4 AND 8 LINES CONVENTIONAL
• The FIREscape expansion card is needed when a third or fourth • fire alarm / reporting center
• equipped with a fire department key EN54-2, EN54-4
HOAN or HOCO card is to be attached
approved
HEDRING.NET • maximum battery size 7 Ah 12V 2 ea/center
ADDITIONAL CARD FOR NETWORKABLE CENTERS • IP30
• Additional card needed for networking Firescape • Hochiki conventional detectors and buttons as network
centers devices
• sturdy metal case
FS-UP
FIREscape KEYPAD/FIN HED-GRAPHICS
• 8 keypads can be connected to FIREscape centers GRAPHICS SOFTWARE
• graphical display 64 x 264 pixels • versatile, simultaneous graphics software for
• connection: RS485
• can be placed approximately 500 m from the center without multiple systems
• ability to zoom in on layout templates
channel amplification • several presentation levels
• the alarm display has the page number for the positioning diagram • connections for HHL, Hedsam, Prodex, Neptolux
• dimensions 355 x 255 x 26 mm
• keypad integrated to door and Smartti systems
FS-UP+BOX-S
FIREscape KEYPAD IN CASE
• Keypad integrated into solid case
• Access right level same as for fire department key, same as the
center
• 8 keypads can be connected to FIREscape centers
• graphical display 64 x 264 pixels
• connection: RS485
• can be placed approximately 500 m from the center without
channel amplification
• the alarm display has the page number for the positioning diagram
FS-BATTERY-BOX
ADDITIONAL BATTERY BOX
• enclosure for additional batteries, max 3 pairs of batteries, total
60 Ah
• if necessary, all batteries can be placed in the additional batter
box, which leaves room in the center case for control units conne-
cted via DIN rails, among others.
PRODEX-KLG
ADRESSABLE ALARM DISPLAY
• for RS485 channel
• information screen only for fire alarm notifications
• displays the same text as the MUP keypad
• several alarms browsing button
• silencing button for internal buzzer
2